Cable penetration

Cables (solar PV, lighting, lightning protection) pass through cable entries, not through the membrane.

Depth
Cable entryDrip loopProtan PVC membraneILLUSTRATIVE SCHEMATIC, NOT A CONSTRUCTION DRAWING.
Illustrative schematic, not a construction drawing.

Cables are grouped and routed through a cable entry or gooseneck so water cannot run along the cable into the building. Cables on the roof must not lie unprotected on the membrane.

Common errors

  • Cable pushed through a slit and sealed with mastic
  • No drip loop
  • Cables abrading the membrane

Cable entry / gooseneck

Not yet technically reviewedSources: stogrenta.lt (2017) — company installation practice texts